https://www.enterair.pl/slot-gacor/

CLINICAL AND DIAGNOSTIC EFFICACY OF MULTIPARAMETRIC ELASTOGRAPHY IN DIFFUSE LIVER DISEASES

  • A. V. Borsukov State Educational Government-Financed Institution of Higher Professional Education «Smolensk State Medical University»
  • T. G. Morozova State Educational Government-Financed Institution of Higher Professional Education «Smolensk State Medical University»
  • A. O. Bueverov Institute of Professional Education at Federal State Autonomous Educational Institution of Higher Education «I.M. Sechenov First Moscow State Medical University»
Keywords: multiparametric elastography, diffuse liver diseases

Abstract

Background. The use of elastography methods is the current stage of the algorithm of patients’ examination in modern hepatology.
Objective. Analysis of the up-to-date opportunities of a multiparametric elastography approach in the diagnosis of diffuse liver diseases.
Materials and methods. A survey of 235 patients (aged 21 to 62 years old) suffering from various clinical forms of diffuse liver diseases was performed. Among them, there were 128 (54.5%) men and 107 (45.5%) women. The patients were randomized into 3 groups. The first group included 64 (27.2%) patients with steatogepatitis, the second – 97 (41.3%) patients with hepatitis, the third - 74 (31.5%) subjects with Child-Pugh class B cirrhosis. Using multiparametric elastography was obligatory in the algorithm of patients’ examination. Results. In the first phase of examination of the patients the sensitivity and specificity of the liver biopsy and multiparametric elastography had high informative value (AUROC 0.992, CI 0.893 – 0.998 and AUROC 0.889, CI 0.632 – 0.995, respectively). During the dynamic observation of patients who followed the doctor’s recommendations the sensitivity and specificity of multiparametric elastography were highly informative (AUROC 0.991, СI 0.779 - 0,997), as was the liver biopsy ( AUROC 0.882, CI 0.741 – 0. 996). During the dynamic observation of patients with negative clinical laboratory and instrumental dynamics we received the following values: for biopsy – AUROC 0.999, СI 0.996 – 1.000, for multiparametric elastography – AUROC 0.881, СI 0.632-0.901.
Conclusion. The results of using multiparametric elastography allows us to consider it as a universal screening method of diagnosis of the liver fibrosis process both at entry and during the dynamic monitoring of patients.

References


1. Ferraioli G, Filice C, Castera L, Choi BI, Sporea I, Wilson SR, Cosgrove D, Dietrich CF, Amy D, Bamber JC, Barr R, Chou YH, Ding H, Farrokh A, Friedrich-Rust M, Hall TJ, Nakashima K, Nightingale KR, Palmeri ML, Schafer F, Shiina T, Suzuki S, Kudo M. WFUMB guidelines and recommendations for clinical use of ultrasound elastography. Part 3: Liver. Ultrasound Med. Biol. 2015;41(5):1161-1179. doi: 10.1016/j.ultrasmedbio.2015.03.007.


2. Dietrich CF, Bamber J, Berzigotti A, Bota S, Cantisani V, Castera L, Cosgrove D, Ferraioli G, Friedrich-Rust M, Gilja OH, Goertz RS, Karlas T, de Knegt R, de Ledinghen V, Piscaglia F, Procopet B, Saftoiu A, Sidhu PS, Sporea I, Thiele M. EFSUMB guidelines and recommendations on the clinical use of liver ultrasound elastography, Update 2017 (Long Version). Ultrashall Med. 2017;38(04):e16-e47. doi: 10.1055/s-0043-103952.


3. Bamber J, Cosgrove D, Dietrich CF, Fromageau J, Bojunga J, Calliada F, Cantisani V, Correas JM, D’Onofrio M, Drakonaki EE, Fink M, Friedrich-Rust M, Gilja OH, Havre RF, Jenssen C, Klauser AS, Ohlinger R, Saftoiu A, Schaefer F, Sporea I, Piscaglia F. EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography. Part 1: Basic Principles and Technology. Ultraschall Med. 2013;34(2):169-184. doi: 10.1055/s-0033-1335205.


4. Cosgrove D, Piscaglia F, Bamber J, Bojunga J, Correas JM, Gilja OH, Klauser AS, Sporea I, Calliada F, Cantisani V, D’Onofrio M, Drakonaki EE, Fink M, Friedrich-Rust M, Fromageau J, Havre RF, Jenssen C, Ohlinger R, Săftoiu A, Schaefer F, Dietrich CF. EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography. Part 2: Clinical Applications. Ultraschall Med. 2013;34(3):238-253. doi: 10.1055/s-0033-1335375.


5. Morozova TG, Borsukov AV. Jendosonograficheskij monitoring v kompleksnoj diagnostike zabolevanij gepatopankreatoduodenalnoj zony i zheludka [Endosonography monitoring in the diagnosis of diseases of hepatopancreatoduodenal zone and stomach]. Klinicheskaja praktika [Clinical practice]. 2014;2(18):35-41. (Russian).


6. Borsukov AV, Andreev VG, Gelt TD, Gurbatov SN, Demin IJu, Ivanova EV, Kovalev AV; Borsukov AV, editor. Jelastografija sdvigovoj volny: analiz klinicheskih primerov [Elastography of shear wave: analysis of clinical examples]. Smolensk: Smolenskaja gorodskaja tipografija; 2017. 374 p. (Russian).


7. Morozova TG, Borsukov AV. Jelastografija pri jendosonografii organov gepatopankreatoduodenalnoj zony: novoe napravlenie diagnostiki [Elastography in endosonog-raphy of hepatopancreatoduodenal zone: new direction in diagnostic]. Uchenye zapiski Orlovskogo gosudarstvennogo universiteta. Serija: Estestvennye, tehnicheskie i medicinskie nauki. 2014;3(59):239-243. (Russian).


8. Ferraioli G, Tinelli C, Zicchetti M, Above E, Poma G, Di Gregorio M, Filice C. Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity. Eur. J. Radiol. 2012;81(11):3102-3106. doi: 10.1016/j.ejrad.2012.05.030.

Published
2019-02-05
How to Cite
1.
Borsukov AV, Morozova TG, Bueverov AO. CLINICAL AND DIAGNOSTIC EFFICACY OF MULTIPARAMETRIC ELASTOGRAPHY IN DIFFUSE LIVER DISEASES. journalHandG [Internet]. 2019Feb.5 [cited 2024Jun.13];1(2):135-9. Available from: http://www.pkc.grsmu.by/index.php/journalHandG/article/view/20
Section
Оригинальные исследования
https://uni.sesc.com.br/rajaslot303/slot gacor 2024slot gacor gampang menangslot gacor gampang menang